Signal Flow Graph of Control System

Encyclopedia
09/15/2024 15:55:01

Signal Flow Graph Definition


A signal flow graph simplifies control system diagrams by using nodes and branches instead of blocks and summing points.

 

1.jpeg


Rules for Drawing Signal Flow Graph


  • The signal always travels along the branch towards the direction of indicated arrow in the branch.



  • The output signal of the branch is the product of transmittance and input signal of that branch.



  • Input signal at a node is summation of all the signals entering at that node.



  • Signals propagate through all the branches, leaving a node.

 

2.jpeg

 22.jpeg

Simple Process of Calculating Expression of Transfer Function for Signal Flow Graph


  • First, calculate the input signal at each node of the graph. This is done by summing the products of transmittance and the variables at the other ends of branches pointing to the node.



  • Now by calculating input signal at all nodes will get numbers of equations which relating node variables and transmittance. More precisely, there will be one unique equation for each of the input variable node.



  • By solving these equations we get, ultimate input and output of the entire signal flow graph of control system.



  • Lastly by dividing inspiration of ultimate output to the expression of initial input we calculate the expiration of transfer function of that signal flow graph

 

3.jpeg

 

33.jpeg

 333.jpeg

3333.jpeg

If P is the forward path transmittance between extreme input and output of a signal flow graph. L1, L2…………………. loop transmittance of first, second,.….. loop of the graph. Then for first signal flow graph of control system, the overall transmittance between extreme input and output is


For the second signal flow graph of a control system, the overall transmittance between the input and output is calculated similarly.


Here in the figure above, there are two parallel forward paths. Hence, overall transmittance of that signal flow graph of control system will be simple arithmetic sum of forward transmittance of these two parallel paths.

 

4.jpeg

 41.jpeg

As the each of the parallel paths having one loop associated with it, the forward transmittances of these parallel paths are


Therefore overall transmittance of the signal flow graph is

 

5.jpeg

 

Mason’s Gain Formula

 

6.jpeg

 61.jpeg

The overall transmittance or gain of a signal flow graph in a control system is given by Mason’s Gain Formula.


7.jpeg

 


Where, P k is the forward path transmittance of kth in path from a specified input is known to an output node. In arresting Pk no node should be encountered more than once.


Δ is the graph determinant which involves closed loop transmittance and mutual interactions between non-touching loops.


Δ = 1 – (sum of all individual loop transmittances) + (sum of loop transmittance products of all possible pair of non-touching loops) – (sum of loop transmittance products of all possible triplets of non-touching loops) + (……) – (……)


Δ k is the factor associated with the concerned path and involves all closed loop in the graph which are isolated from the forward path under consideration.


The path factor Δk for the kth path is equal to the value of grab determinant of its signal flow graph which exist after erasing the Kth path from the graph.


By using this formula one can easily determine the overall transfer function of control system by converting a block diagram of control system (if given in that form) to its equivalent signal flow graph. Let us illustrate the below given block diagram.

 

f32efc5ef88df75627102583bab18e70.jpeg

bcb4ee31e71500a1be0ecb5e9a298245.jpeg



35a0a09b2c6b76c955ef429d9b82ea5b.jpeg

Master Electrician