What is Phasor Diagram for Synchronous Motor?

Encyclopedia
08/17/2024 09:11:20


What is Phasor Diagram for Synchronous Motor?


Phasor Diagram Definition


A phasor diagram for a synchronous motor shows the relationships between various electrical quantities like voltage and current.

 

9bc16c7564c829cfbdd752fa0badcc88.jpeg

 

Ef to represent the excitation voltage


Vt to represent the terminal voltage


Ia to represent the armature current


Θ to represent the angle between terminal voltage and armature current


to represent the angle between the excitation voltage and armature current


δ to represent the angle between the excitation voltage and terminal voltage


ra to represent the armature per phase resistance.

 

 


Reference Phasor


Vt is the reference phasor, with armature current and excitation voltage being plotted in relation to it.

 


Opposite Phases


The armature current is in phase opposition to the excitation emf in a synchronous motor.

 


Power Factor Operations


Different power factor operations (lagging, unity, leading) affect the expressions for the excitation emf, using components of terminal voltage and armature current.

 

47c2b279412ebb497c17a6aaa4f81029.jpeg

 


 Motoring operation at lagging power factor.


Motoring operation at lagging power factor: In order to derive the expression for the excitation emf for the lagging operation we first take the component of the terminal voltage in the direction of armature current Ia. Component in the direction of armature current is VtcosΘ.

As the direction of armature is opposite to that of the terminal voltage therefore voltage drop will be –Iara hence the total voltage drop is (VtcosΘ – Iara) along the armature current. Similarly we can calculate the voltage drop along the direction perpendicular to armature current. The total voltage drop comes out to be (Vtsinθ – IaXs). From the triangle BOD in the first phasor diagram we can write the expression for excitation emf as

 



Motoring operation at unity power factor.


Motoring operation at unity power factor: In order to derive the expression for the excitation emf for the unity power factor operation we again first take the component of the terminal voltage in the direction of armature current Ia. But here the value of theta is zero and hence we have = δ. From the triangle BOD in the second phasor diagram we can directly write the expression for excitation emf as

 

d9d9284a6e9f5bb3e1a557dc1840ed9b.jpeg

 


Motoring operation at leading power factor.

 


Motoring operation at leading power factor: In order to derive the expression for the excitation emf for the leading power factor operation we again first take the component of the terminal voltage in the direction of armature current Ia. Component in the direction of armature current is VtcosΘ. As the direction of armature is opposite to that of the terminal voltage therefore voltage drop will be (–Iara) hence the total voltage drop is (VtcosΘ – Iara) along the armature current. Similarly we can calculate the voltage drop along the direction perpendicular to armature current. The total voltage drop comes out to be (Vtsinθ + IaXs). From the triangle BOD in the first phasor diagram we can write the expression for excitation emf as

 

b700ff88c140e247006993dcfeb1c021.jpeg

 

Advantages of Phasor Diagrams


  • Phasors are highly useful for gaining physical insight into the operation of the synchronous motors.


  • We can derive mathematical expressions for various quantities easily with the help of phasor diagrams.