Brand | Wone |
Model NO. | Outdoor portable power station |
Rated Output Rating | 5kW |
Energy storage capacity | 4.8kWh |
Series | OP series |
Outdoor portable power station
Peculiarity:
♦ Light weight, high capacity, stable power.
♦ Rich interface, compatible with USB-A,USB-C,DC interface, cigarette lighter and other mainstream DC interface, and can provide 20~100W stable output.
♦ Complete protection functions, high safety performance.
♦ Support battery pack voltage and capacity customization to meet different use environments.
♦ Mature technology, long cycle life.
♦ Modular design, high power density, easy maintenance
Technical parameter:
Product model |
OP-600-576 |
Battery capacity |
576WH |
Rated discharge current |
50A |
Maximum discharge current |
100A |
Voltage range |
10~16.8V |
Standard battery unit voltage |
14.4V |
Maximum DC charging voltage |
16.8V |
Rated output power |
0.6kW |
Inverter mode |
Single phase inverter |
Power input voltage |
AC 170~280V |
Input frequency |
45~65Hz |
Maximum PV input power |
100W |
Interface Overview |
2*DC 100W 12.5V 8A 1*Car cigarette lighter 12.5V 8A 2*USB QC3.0 2*USB-C PD100W 1*Wireless charging 12V 1.25A 1*AC socket 220V 50HZ (Chinese main land) |
Size(mm) |
265*200*195 |
Weight(kg) |
4.9 |
Protection |
Under (over) voltage protection/Overload protection/Over temperature protection/Short circuit protection/Over discharge protection |
Inverter efficiency |
86%~94% |
Cooling mode |
Forced air cooling |
Operating environment |
Temperature: -0~40℃ Humidity: 45~85RH% |
Maximum working altitude |
2000m(> 2000m load reduction required) |
Class of protection |
IP53 |
Operation mode |
PV priority/battery priority |
Product model |
OP-1200-1008 |
OP-1500-1536 |
|
Battery capacity |
1008WH |
1536WH |
|
Rated discharge current |
100A |
60A |
|
Maximum discharge current |
200A |
90A |
|
Voltage range |
11~16.8V |
22~29.2V |
|
Standard battery unit voltage |
14.4V |
25.4V |
|
Maximum DC charging voltage |
16.8V |
29.2V |
|
Rated output power |
1.2kW |
1.5kW |
|
Inverter mode |
double phase inverter |
double phase inverter |
|
Power input voltage |
AC 170~280V |
||
Input frequency |
45~65Hz |
||
Maximum PV input power |
550W |
800W |
|
Interface Overview |
2*DC 100W 12.5V 8A 1*Car cigarette lighter 12.5V8A 1*USB QC3.0 1*USB-C PD60W 2*USB 5V 2.4A 2XUSB-C 5V 2.4A 1*Wireless charging 12V 1.25A 3*AC socket 220V 50HZ (Chinese main land) |
2*DC 100W 12.5V 8A 1*Car cigarette lighter 12.5V8A 1*USB QC3.0 1*USB-C PD60W 2*USB 5V 2.4A 2XUSB-C 5V 2.4A 1*Wireless charging 12V 1.25A 3*AC socket 220V 50HZ (Chinese main land) |
|
Size(mm) |
370*245*275 |
390*290*295 |
|
Weight(kg) |
13 |
22.5 |
|
Protection |
Under (over) voltage protection/Overload protection/Over temperature protection/Short circuit protection/Over discharge protection |
||
Inverter efficiency |
86%~94% |
||
Cooling mode |
Forced air cooling |
||
Operating environment |
Temperature: -0~40℃ Humidity: 45~85RH% |
||
Maximum working altitude |
2000m(> 2000m load reduction required) |
||
Class of protection |
IP53 |
||
Operation mode |
PV priority/battery priority |
Product model |
OP-2000-1843 |
OP-3000-3024 |
|
Battery capacity |
1843WH |
2880WH |
|
Rated discharge current |
80A |
120A |
|
Maximum discharge current |
120A |
150A |
|
Voltage range |
19.25~29.4V |
19.25~29.4V |
|
Standard battery unit voltage |
25.2V |
25.2V |
|
Maximum DC charging voltage |
29.4V |
29.4V |
|
Rated output power |
2kW |
3kW |
|
Inverter mode |
double phase inverter |
double phase inverter |
|
Power input voltage |
AC 170~280V |
||
Input frequency |
45~65Hz |
||
Maximum PV input power |
800W |
1000W |
|
Interface Overview |
2*DC 100W 12.5V 8A 1*Car cigarette lighter12.5V 8A 1*USB QC3.0 1*USB-C PD60W 2*USB 5V 2.4A 2XUSB-C 5V 2.4A 1*Wireless charging 12V 1.25A 3*AC socket 220V 50HZ (Chinese main land) |
2*DC 100W 12.5V 8A 1*Car cigarette lighter 12.5V8A 1*USB QC3.0 1*USB-C PD60W 2*USB 5V 2.4A 2XUSB-C 5V 2.4A 1*Wireless charging 12V 1.25A 3*AC socket 220V 50HZ (Chinese main land) |
|
Size(mm) |
400*300*322 |
400*300*322 |
|
Weight(kg) |
25 |
28 |
|
Protection |
Under (over) voltage protection/Overload protection/Over temperature protection/Short circuit protection/Over discharge protection |
||
Inverter efficiency |
86%~94% |
||
Cooling mode |
Forced air cooling |
||
Operating environment |
Temperature: -0~40℃ Humidity: 45~85RH% |
||
Maximum working altitude |
2000m(> 2000m load reduction required) |
||
Class of protection |
IP53 |
||
Operation mode |
PV priority/battery priority |
Product model |
OP-3200-3K |
OP-3000-3024 |
|
Battery capacity |
2560WH |
4800WH |
|
Rated discharge current |
120A |
100A |
|
Maximum discharge current |
150A |
150A |
|
Voltage range |
19.25~29.4V |
44~58.4V |
|
Standard battery unit voltage |
25.2V |
51.2V |
|
Maximum DC charging voltage |
29.4V |
58.4V |
|
Rated output power |
3.2kW |
5kW |
|
Inverter mode |
Integrated inverter &control |
Integrated inverter & control |
|
Power input voltage |
AC 170~280V |
||
Input frequency |
45~65Hz |
||
Maximum PV input power |
4000W |
6000W |
|
Interface Overview |
2*DC 100W 12.5V 8A 1*Car cigarette lighter 12.5V8A 2*USB 5V 2.4A 1*AC socket 220V 50HZ (Chinese main land) |
2*DC 100W 12.5V 8A 1*Car cigarette lighter 12.5V8A 2*USB 5V 2.4A 1*AC socket 220V 50HZ (Chinese main land) |
|
Size(mm) |
500*300*340 |
500*300*340 |
|
Weight(kg) |
42 |
55 |
|
Protection |
Under (over) voltage protection/Overload protection/Over temperature protection/Short circuit protection/Over discharge protection |
||
Inverter efficiency |
86%~94% |
||
Cooling mode |
Forced air cooling |
||
Operating environment |
Temperature: -10~40℃ Humidity: 0~95RH% |
||
Maximum working altitude |
2000m(> 2000m load reduction required) |
||
Class of protection |
IP53 |
||
Operation mode |
PV priority/battery priority |
NOTE:
Optional AC socket
Optional AC socket output standard:
220V 50HZ / 230V 50HZ / 230V 60HZ/
110V 60HZ / 110V50HZ
The output electric energy standard is applicable to most countries or regions such as Chinese mainland, Hong Kong, Macao, North Korea,Japan,Australia, South Asia, the Middle East, Europe, Africa, South America, etc., and customers in non-above regions can customize according to the customer's local electric energy standard.
Specifications |
Unit |
Value |
|||
Rated voltage |
KV |
550 |
|||
Rated current |
A |
6300 |
|||
Rated frequency |
Hz |
50 |
|||
Rated withstand current/time |
KA |
63/3 |
|||
Rated peak withstand current(peak value) |
KA |
171 |
|||
1min rated power frequency withstand voltage (r.m.s) |
To earth & between pole |
KV |
740(+318) |
||
Across isolating distance |
KV |
1675(+450) |
|||
Rated lightning impulse withstand voltage (peak) |
To earth & between pole |
KV |
1675 |
||
To earth & between pole |
KV |
1675(+450) |
|||
partial discharge |
Pre applied voltage |
KV |
740(1min) |
||
testing voltage |
KV |
381 |
|||
Each compartment |
pC |
≤3 |
|||
Each insulation component |
pC |
≤3 |
|||
casing pipe |
pC |
≤3 |
|||
Rated SF6 annual leakage |
% |
≤0.3 |
|||
Switching current of busbar |
Disconnect Switch |
1600A/400V/100 times |
|||
Switching capacitive current |
A |
2 |
|||
Switching inductive current |
A |
1 |
|||
Bus charging current switching test method 3 |
318KV/2A/50 times |
||||
Bus charging current switching test method 1 |
350KV/-494KV/50 times |
||||
Rated short-circuit current closing frequency |
≥2 |
||||
Ability to switching rated capacitive electrostatic induction current |
high speed grounding switches |
50A/100KV/10 times |
|||
Ability to switching rated inductive electromagnetic induction current |
700A/50KV/10 times |
||||
mechanical life |
Times |
10000 |