Brand | Wone |
Model NO. | PV&ESS integrate machine |
Cooling mode | Forced air cooling |
Rated Output Rating | 20kW |
Energy storage capacity | 51.2kWh |
Rated PV input power | 26kW |
Series | KP series |
PV&ESS integrate machine
Peculiarity:
♦ Modular storage parallel design concept, improve system stability, easy installation and maintenance, easy expansion.
♦ Fast realization of grid-connected/off-grid PV collaboration.
♦ Adjustable energy scheduling, users can change the charge and discharge logic according to the power consumption strategy of different periods in the area.
♦ Multiple protection and safety devices to ensure the safety of use.
♦ Energy Balance Management controllers are used to refine energy management of energy storage systems down to the battery PACK level.
♦ Battery PACK horizontal energy balance management controller to avoid capacity loss caused by mismatches.
♦ Outdoor modular energy storage converter cabinet design, high power density, easy maintenance.
Technical parameter:
Product model |
KP-20-50K |
KP-30-60K |
KP-50-107K |
KP-100-215K |
Battery capacity |
51.2kWH |
61.44kWH |
107kWH |
215kWH |
Rated discharge current |
50A |
50A |
75A |
140A |
Maximum discharge current |
100A |
100A |
150A |
280A |
Voltage range |
212-288V |
245-345V |
582-806V |
636-864V |
Standard battery unit voltage |
256V |
307.2V |
720V |
768V |
Maximum DC charging voltage |
288V |
345V |
806V |
864V |
Rated input/output power |
20kW |
30kW |
50kW |
100kW |
Maximum PV input power |
26kW |
35kW |
65kW |
110kW |
Grid input voltage(phase voltage) |
170~280V(UPS)/120~280V(INV) |
|||
Input frequency |
45~65Hz |
|||
Ac access mode |
Three-phase four-wire (three groups of live + neutral) |
|||
Rated output voltage |
230V*3+N (phase voltage) |
The output electric energy standard is applicable to most countries or regions such as Chinese mainland, Hong Kong, Macao, North Korea, Australia, South Asia, the Middle East, Europe, Africa, South America, etc., and customers in non-above regions can customize according to the customer's local electric energy standard. |
||
Rated output frequency |
50HZ±0.2% (60HZ±0.2%) |
|||
System efficiency |
86%~97% |
|||
Output harmonic |
<0.3 |
|||
Cooling mode |
Forced air cooling+ Air conditioning cooling |
|||
Operating environment |
Temperature: -30~50℃ Humidity: 20~95RH% |
|||
Maximum working altitude |
4000m(> 2000m load reduction required) |
|||
Communication mode |
RS485/CAN |
|||
Fire protection installation |
Battery pack aerosol fire extinguishing device+ Cabinet aerosol fire extinguishing device |
|||
Class of protection |
IP54 |
|||
Operation mode |
Mains priority /battery priority |