• 550KV 740KV GIS SF6 insulated Switchgear
550KV 740KV GIS SF6 insulated Switchgear
discuss personally
ZF28-550/4000-63
Basic info
Brand ROCKWILL
Model NO. 550KV 740KV GIS SF6 insulated Switchgear
Rated voltage 550KV
Rated normal current 4000A
Series ZF28
Product Detail

Product Overview:
    ZF28-550 type GIS/ ZH28-550 type HGIS is composed of standard modules through flanged joint, which can meet the demand for substation optimization design through the flexible combination between modules. It saves space and conforms to technical requests.
    This product can be applied to power system, power generation, rail transportation, petrochemical, metallurgy, mining, building materials and other large industrial consumer.

Features and advantages of the product:

  • Fully spring mechanism, high reliability;

  • Excellent breaking ability;

  • The arc extinguish of CB adopts dual break structure, and shunt capacitor to balance the voltage between open contacts, which improves the breaking ability of short-line fault and the breaking current of short circuit is 63kA;

  • E2-M2-C2 circuit breaker; E2 electrical endurance; M2 mechanical endurance;

  • Strong rated current flow capacity;

  • Excellent insulation level, low partial discharge;

  • Excellent corrosion resistance;

  • Advanced Designing tool;

  • Basin-type insolator with aluminium flange; double sealing structure;

  • Strict assembly technology;

  • The domestic first high power spring operation mechanism of circuit breaker has the small volume and is safe and stable, free of maintenance. high reliable and conform to oil free and gas free requirements for operation mechanism;

  •  Interrupter unit adopts shunt capacitor to balance the voltage between open contacts It improves short line  fault breaking capability;

  • Excellent insulation level and low partial discharge. The only company in the industry that can achieve: under the 80% power-frequency withstand voltage (80%×740kV = 592kV), the partial discharge of intervals is lower than 5pC, the partial discharge of the insulator is lower than 3pC. It’s better than the IEC standard that the partial discharge should be lower than 5pC under 1.2 times phase voltage (1.2×550/√3 = 381kV);

  • The insulator quality is stable and reliable. The basin-type insulator pouring process reaches the international advanced level;