• Complete Set of Large Capacity 100kA Generator Circuit Breaker
Complete Set of Large Capacity 100kA Generator Circuit Breaker
discuss personally
ZHN10-24/15000-120
Basic info
Brand ROCKWILL
Model NO. Complete Set of Large Capacity 100kA Generator Circuit Breaker
Rated voltage 24KV
Rated normal current 15000
Series Circuit Breaker
Product Detail

This product is suitable for water and thermal power plants with a single generator unit capacity of 300-400 megawatts. It has a large current carrying capacity and strong breaking capacity. It was appraised by the China Machinery Industry Federation in 2019, and its comprehensive technical performance has reached the international leading level. Currently, it has supplied multiple power plants.
Product Performance:
1,Implemented according to the latest lEC standards.
2,High insulation level: meeting the insulation requirements of the products under the environment of 3,000m above sea level.
3,High long-term flow capacity: adopts natural cooling, no auxiliary heat dissipation device, and rated flow capacity up to 15,000A.
4,Excellent breaking performance: The effective values of Ac component of short-circuit breaking current is 100kA and the DC component is as high as 82%, which meets the current breaking requirements under various fault conditions.
5,High mechanical reliability: Innovative design of circuit breaker drive ensures that the product can meet the breaking performance under the small input operation work, and realize the mechanical life requirement of operation for 10,000times.
6,comprehensive safety protection measures: Pressure release device is installed at the top of the circuit breaker When the gas pressure in the arc extinguishing chamber exceeds 1.2Pa due to an accident, the gas will be released to ensure the safety of the personnel and surrounding equipment, The product design can ensure the stable operation of the power plant.
Product Structure:
1,The product consists of three single poles, and each pole has an individual enclosed metal enclosure mounted on the same chassis.
2,Circuit breaker is equipped with hydraulic spring operating mechanism: the disconnector and earthing switch are equipped with motor operating mechanism; the driving modes are all three phase mechanical linkage.
3,The main circuit adopts natural cooling.
4,Each operating mechanism is installed on the side of the product close to the control cabinet.
5,SF6 is used as arc extinguishing and insulation medium for circuit breaker, and the arc extinguishing chamber adopts a new type of arc extinguishing chamber which combines self-energy arc extinguishing with auxiliary air-compressor arc extinguishing, which effectively reduces the operating work and perfectly solves the problem of short-circuit current breaking of various energies.
6,The disconnector and the circuit breaker are connected in series, arranged in the same enclosure, using the air as the insulation medium, the fixed contact is located at the circuit breaker side, and the moving contact is in the telescopic direct-acting structure, which has the advantages of simple structure with small occupancy size and high current capability.
7,The earthing switches are arranged on both sides of the incoming and cut going lines respectively, and using the air as the insulation medium, The fixed contacts are located on the high potential side, which are installed on the support of the main circuit, and the moving side is installed on the bottom plate of the box body. The moving contacts are connected with the single-phase enclosure and form earthing loop through the metal-enclosed isolated phase busbars connected with the moving contacts.
微信图片_20240615104709_修复后.png

Typical applications:
微信图片_20240615104755_修复后.png

微信图片_20240615104813_修复后.png

Main technical parameters

NO

Item

Unit

Parameters

Remarks

1

Rated voltage

KV

24

The product meets the service environment   of 3,000mabove sea level.

2

Rated current

A

15000

3

Rated frequency

Hz

50

4

Rated insulation level

Short-time power frequency withstand   voltage(1min)

KV

65

Lightning impulse withstand voltage(peak)

125

5

Rated short circuit breaking current

KA

100

6

Rated short circuit making current(peak)

274

7

Mechanical  life

Circuit breaker

times

10000

Disconnector/Earthing switch

10000


Other recommendations for your business
New Knowledges
Inquiry
Free Download Now
Wone is dedicated to serving the personnel in the global power industry.
Join WONE, not only can you discover power equipment and power knowledge, but also can find like-minded friends!