Brand | Wone |
Model NO. | Rack mounted ESS |
Rated Output Rating | 5kW |
Energy storage capacity | 20.48kWh |
Cell quality | Class A |
Series | CESS series |
Rack mounted ESS
Peculiarity:
♦ Compact size and no installation.
♦ Battery pack is replaceable, can be adapted to a variety of batteries, for different batteries to achieve different charging and discharging strategies.
♦ Energy scheduling can be regulated, users can change the charge and discharge according to the power consumption policy of different periods in the region; Low logical O&M cost.
♦ Support battery pack voltage, capacity customization, to meet different use environment
♦ Mature technology, long cycle life, high safety performance.
♦ Modular design, high power density, easy maintenance.
Technical parameter:
Product model |
CESS -5- 5K |
CESS-5-10K |
CESS-5-15K |
CESS-5-20K |
CESS-5-25K |
Battery capacity |
5.12kWH |
10.24kWH |
15.36kWH |
20.48kWH |
25.6kWH |
Rated discharge current |
50A |
50A |
50A |
50A |
50A |
Maximum discharge current |
100A |
100A |
100A |
100A |
100A |
Voltage range |
43.2~57.6V |
43.2~57.6V |
43.2~57.6V |
43.2~57.6V |
43.2~57.6V |
Standard battery unit voltage |
51.2V |
51.2V |
51.2V |
51.2V |
51.2V |
Maximum DC charging voltage |
57.6V |
57.6V |
57.6V |
57.6V |
57.6V |
Single Cluster Battery Pack |
16S1P |
16S2P |
16S3P |
16S4P |
16S5P |
Rated output power |
5kW |
5kW |
5kW |
5kW |
5kW |
Product model |
CESS -10- 20K |
CESS-15-30K |
CESS-20-40K |
CESS-25-50K |
CESS-30-60K |
Battery capacity |
20.48kWH |
30.72kWH |
40.96kWH |
51.2kWH |
61.44kWH |
Rated discharge current |
50A |
150A |
200A |
250A |
300A |
Maximum discharge current |
100A |
300A |
400A |
500A |
600A |
Voltage range |
43.2~57.6V |
43.2~57.6V |
43.2~57.6V |
43.2~57.6V |
43.2~57.6V |
Standard battery unit voltage |
51.2V |
51.2V |
51.2V |
51.2V |
51.2V |
Maximum DC charging voltage |
57.6V |
57.6V |
57.6V |
57.6V |
57.6V |
Single Cluster Battery Pack |
16S4P |
16S6P |
16S8P |
16S10P |
16S12P |
Rated output power |
5kWx2 |
5kWx3 |
5kWx4 |
5kWx5 |
5kWx6 |
Rated PV charging voltage |
360VDC |
||||
MPPT tracking range |
120-450V |
||||
MPPTMPPT track number |
1 |
||||
Grid input voltage(phase voltage) |
170~280V(UPS)/120~280V(INV) |
||||
Input frequency |
45~65Hz |
||||
Maximum grid input current |
60A single |
||||
Maximum PV input current |
100A single |
||||
Ac access mode |
Single line+Neutral line |
||||
Rated output voltage |
230V+N |
The output electric energy standard is applicable to most countries or regions such as Chinese mainland, Hong Kong, Macao, North Korea, Australia, South Asia, the Middle East, Europe, Africa, South America, etc., and customers in non-above regions can customize according to the customer's local electric energy standard. |
|||
Rated output frequency |
48~52HZ (58~62HZ) |
||||
System efficiency |
86%~94% |
||||
Output harmonic |
<0.3 |
||||
Cooling mode |
Forced air cooling |
||||
Operating environment |
Temperature: -30~50℃ Humidity: 20~95RH% |
||||
Maximum working altitude |
4000m(> 2000m load reduction required) |
||||
Fire protection installation |
HFC-227ea/FM200 gas fire extinguishing device |
||||
Class of protection |
IP20 |
||||
Operation mode |
Mains priority/PV priority/battery priority |
Note:
1. The A-class cell can charge and discharge 6000 times, and the B-class cell can charge and discharge 3000 times, and the default discharge ratio is 0.5C.
2. Class A cell warranty 60 months, Class B cell warranty 30 months.