Brand | ROCKWILL |
Model NO. | RCW E27G MV outdoor vacuum recloser |
Rated voltage | 27kV |
Rated normal current | 400A |
Rated short circuit breaking current | 12.5kA |
Power frequency withstand voltage | 70kV/min |
Rated lightning impulse voltage | 150kV |
manual closing | Yes |
Series | RCW |
Description
The RCW series automatic circuit reclosers can use on overhead
distribution lines as well as distribution substation applications for all
voltage classes 11kV up to 38kV at 50/60Hz power system. and it’s rated
current can reach 1250A.
The RCW series automatic circuit reclosers integrates the functions of
control, protection, measurement, communication, fault detection, on-line
monitoring of closing or opening.
The RCW series vacuum recloser is mainly combined with integration
terminal, current transformer, permanent magnetic actuator and it’s
recloser controller.
Features
Optional grades available in rated current range.
With optional relay protection and logic for user selection.
With optional communication protocols and I/O ports for users to choose.
PC software for controller testing, setup, programming, updates.
Parameters
Rated maximum voltage |
27KV |
|
Rated maximum current |
400A |
|
Rated frequency |
50Hz |
|
Rated short circuit breaking current |
12.5KA |
|
Rated peak value withstand current |
31.5KA |
|
Rated 1min power frequencywithstand voltage(Three-phase Silicone rubber pole (unable the gas)) |
70KV |
|
Rated lightning impulse voltage(Three-phase Silicone rubber pole (unable the gas)) |
150KV |
|
Operation sequence |
C-0.5-CO-2-CO-5-CO(Magnetic actuator) |
|
Mechanical life |
n:30000(Magnetic actuator) |
|
Power supply and operating voltage |
110/220V( Customized) |
|
Ratio of current transformer |
400/1A( Customized) |
|
Number of voltage sensors(Three-phase Silicone rubber pole (unable the gas)) |
≤3 |
|
Opening time |
≤30ms(Magnetic actuator) |
|
Closing time |
≤40ms(Magnetic actuator) |
|
Minimum creepage distance |
31,level4(mm/kv) |
|
Minimum distance between phases |
380mm |
|
Potential transformer |
110/220V( Customized) |
|
Cable length |
6,8,12m( Customized) |
|
Cable clamp(Three-phase Silicone rubber pole (unable the gas)) |
2-hole NEMA |
|
Lightning arrester |
≤6 |
|
Mounting type |
Single / double column |
With optional relay protection& logics for user choice |
Instantaneous over-current protection |
|
Timing over-current protection |
||
Negative sequence over-current protection |
||
Directional over-current protection(*) |
||
Over-voltage protection./Under voltage protection |
||
Programable protection relay curves total 10 nos ANSI/IEC curves |
||
Cold load pickup protection TCC +Hot line tag |
||
Earth protection EF/SEF +Zone Sequence Co-ordination |
||
More relay functions can be customized |
||
With optional communication protocols & I/O port for user choice |
RS-232 and RS-485 ports supporting |
|
DNP3.0 communication protocol support(*) |
||
Modbus communication protocol is optional(*) |
||
IEC 60870-5-101 communication protocol support |
||
IEC 60870-5-104 communication protocol support.(*) |
||
The recloser can communicate through GPRS(Or GSM) modem with English or Specified language (*) |
||
With optional functions for use |
Rated currents, System phase current. |
|
Rated voltages, System phase voltage& secondary low voltage power supply voltage. Frequency, power(kWh), reactive power(kV arh), power factor |
||
With optional reclosing interval for user pre-program |
Reclosing times setting support |
|
Dead time setting support |
||
With events recording function |
SOE 10000 operations record |
|
Fault record and normal operation record |
||
Note: (*) mean should customized by manufacturer if needed |
External dimensions
Environmental requirement
Maximum temperature: |
+40℃ |
Minimum temperature: |
-30℃ |
Monthly average humidity |
95% |
Humidity: |
90% |
Above sea level: |
2500m or higher |
Ambient air not apparently polluted by corrosive and flammable gas, vapor |
Product show