• 126KV 252KV 363KV 420KV 550KV series disconnector
126KV 252KV 363KV 420KV 550KV series disconnector
discuss personally
GW16B-550/4000-63
GW16B-550/3150-50
GW16B-420/3150-50
GW16B-363/5000-63
GW16B-363/3150-50
GW16B-252/5000-63
GW16B-252/3150-50
GW16B-126/3150-40
GW16B-126/2500-40
Basic info
Brand ROCKWILL
Model NO. 126KV 252KV 363KV 420KV 550KV series disconnector
Rated voltage 126KV
Rated normal current 2500A
Series GW
Product Detail

Description

GW16 series disconnector adopts single-column single-arm vertical telescopic structure, which is mainly composed of base, insulator, conductive system, operating mechanism, etc. The disconnector is operated by CJ11 motor operating mechanism for opening and closing. The attached ground switch is mainly composed of ground switch system and operating mechanism, and each group of ground switches is operated by a CJ11 motor operating mechanism for opening and closing.


Main Features


  •  Simple and compact structure, small footprint.

  • Strong product flow capacity, long mechanical life.

  • Optimized spring design, light and smooth operation.

  •  High seismic performance, can resist nine degrees of earthquake intensity.

  • The layout is flexible, convenient for users to choose.

Technical parameter


Specifications

Unit

Value

Model


GW16/16B-126

GW16B-252

GW16B-363

GW16B-420

GW16B-550

Rated voltage

kV

126

252

363

420

550

Rated current

A

2500/3150

3150/5000

3150/5000

3150

3150/4000

Rated frequency

HZ

50

50

50/60

50

50

1min power frequency withstand voltage (r.m.s)

Phase to phase/

to earth

kV

230

460

510

520

740

Across isolating distance

kV

230(+73)

460(+146)

510(+210)

610

740(+315)

Lightning impulse withstand voltage (peak 1.2/50us

Phase to phase/

to earth

kV

550

1050

1175

1425

1675

Across isolating distance

kV

550(+103)

1050(+206)

1175(+295)

1425(+240)

1675(+450)

Rated operating impulse withstand voltage(peak 250/2500μs)

Phase to phase/to earth

kV

\

\

950

1050

1300

Across isolating distance

kV

\

\

850(+295)

900(+345)

1175(+450)

Rated short-time withstand current (r.m.s)

kA

40

50/63

50/63

50

50/63

Rated peak withstand time

kA

100

135/160

125/160

130

125/160

Rated short-circuit withstand time

S

3

3

3

3

3

Wiring terminal static mechanical load

Longitudinal

N

1250

2000

2000

4000

4000

Horizontal

750

1500

1500

1600

2000

Vertical

1000

1250

1500

1500

1500

Operational altitude

m

≤2000

≤2000

≤2000

≤1000

≤1000

Operating pollution class

Class

AG5

AG5

AG3/AG5

AG5

AG3

Mechanical life

Times

5K

10K

5K/3K

10K

10K

Radio interference level

uV

≤500

≤500

≤500

≤500

≤500

bus-transfer current switching by   disconnector

bus-transfer current

A

1600

1600

1600

1600

1600

bus-transfer voltage

V

100

300

300

300

400

disconnector switch capacitive open current

A

1

1

2

1

2

disconnector switch inductive open current

A

0.5

0.5

1

0.5

1

The switching induced current capacity of the   earthing switch

Electromagnetic induction current

A

50/80

80/160

80

80

80

Electromagnetic induction voltage

kV

0.5/2

1.4/15

2

2

2

Electrostatic induction current

A

0.4/2

1.25/10

1.25

1.25

2

Electrostatic induction voltage

kV

3/6

5/15

5

5

8



Other recommendations for your business
New Knowledges
Inquiry
Free Download Now
Wone is dedicated to serving the personnel in the global power industry.
Join WONE, not only can you discover power equipment and power knowledge, but also can find like-minded friends!